Curing Chamber Controllers: The Specs That Matter
A curing chamber controller is a plug-in box that switches your fridge, heater, humidifier or dehumidifier on and off from a probe reading. Before you buy one, check six things: which devices it can run at the same time, its amp limit, its differential (how far the reading drifts before anything switches), its accuracy, whether it has a compressor delay, and whether you can calibrate it. Then change the factory settings. Our read of the three manuals we looked at: the defaults aren't set up for a salami chamber.
This page compares the published specs of three plug-in controllers people use for curing fridges: the INKBIRD ITC-308 (temperature), the INKBIRD IHC-200 (humidity) and the Auber Instruments TH330B (temperature and humidity in one unit). They're examples, not picks. We haven't tested any of them, and every number below is the maker's own, from the manual or product page we opened on November 24, 2026. For what the chamber itself has to do, start with our home curing chamber guide.
Side-by-side: what the makers publish
All values are maker claims, checked November 24, 2026.
| Spec | INKBIRD ITC-308 | INKBIRD IHC-200 | Auber TH330B |
|---|---|---|---|
| Controls | Temperature | Humidity | Temperature and humidity |
| Outlets | 2: a heating outlet and a cooling outlet | 2: a humidifying outlet and a dehumidifying outlet | 2: one for heating or cooling, one for humidifying or dehumidifying |
| Load limit | 10 A total, 1200 W at 120 V (manual) | 10 A max power output (relays 12 A) | 15 A per outlet, 15 A combined |
| Accuracy | ±1°C / ±2°F | ±3% RH | 0.5°C; 4% RH (manual; product page lists 3% RH) |
| Differential, default | 3°F in °F mode; 2.0°C in °C mode | 5% RH each way | 3.0°F; 3.0% RH |
| Differential, range | 1 to 30°F in °F mode; 0.3 to 15°C in °C mode | 1 to 20% RH | 0 to 50.0 degrees; 0 to 50.0% RH |
| Compressor delay, default | 0 minutes (0 to 10) | 1 minute (0 to 10) | 0 minutes (0 to 12) |
| Calibration offset | -15 to +15°F (or °C) | -10 to 10% RH | -10.0 to 10.0 degrees; -10.0 to 10.0% RH |
| Sensor | NTC probe, attached, 2 m (6.56 ft) | HTG3535CH sensor, 2 m (6.56 ft) | 2-in-1 temperature and humidity module, 6 ft (2 m) |
| Alarms, default | High 248°F, low -40°F | High 99% RH, low 0% RH | High 95.0°F, low 32.0°F; humidity high 90.0%, low 10.0% |
Sources: INKBIRD ITC-308 product page and ITC-308 manual; INKBIRD IHC-200 manual; Auber TH330B product page and TH330B manual. The TH330B manual's parameter table lists temperature in Fahrenheit as the initial unit.
Outlets: what can run at the same time
Check this one first, because it decides whether your chamber can warm up at all. A fridge only cools. BCCDC's dry-sausage fermentation range is "20-24°C for dry sausages," which is 68 to 75°F, so a fridge chamber that ferments in the box usually needs a heater on the same controller (BCCDC 3.13).
- The ITC-308 has "Dual Relay Output : Controls heating and cooling independently," with a heating outlet and a cooling outlet (INKBIRD ITC-308).
- The IHC-200 "can control any 100-265 volt humidifier, dehumidifier or fan" and switches "between humidification and dehumidification automatically" (IHC-200 manual).
- The TH330B has "one output socket for each channel." Its temperature socket is set to either heating or cooling, and its humidity socket to either humidifying or dehumidifying. Auber's own note: "If you need to control a heater and a cooler at the same time," use its TD130 dual-channel temperature controller or two TH330B units, and the same goes for a humidifier plus a dehumidifier with its HD330 (Auber TH330B).
So the question isn't "temperature and humidity, yes or no." It's "how many devices, and which ones, need power at once?"
Amp and watt limits
This part's serious. Every device you plug into a controller shares its limit, and the makers set those limits differently.
- ITC-308. The manual lists input and output as "120Vac 60Hz 10A/1200W MAX," with the output limit covering the "total two receptacles." The product page's feature list says "1100W Load Capacity : Supports high-power devices at 110V," while its spec table says "120VAC 60Hz 10A / 1200W (total two receptacles) MAX." The troubleshooting section also lists "heater or cooler exceeds the power limit" as a reason the unit won't power on (ITC-308 manual; ITC-308 page).
- IHC-200. The spec table gives "Power Output Max. 10A, 100V ~240V AC," while the relay contact capacity is listed as 12A for each mode (IHC-200 manual).
- TH330B. "Although both temperature and humidity output can handle up to 15A, the combined total power of the two channels are limited to 15A due to the limitation of input power cord" (TH330B manual).
Our call: when a maker gives two numbers, plan around the lower one (10 A for both INKBIRD units, and 1100 W if you go by the ITC-308 product page). Add up the amps on the rating labels of everything you'll plug in, heater and fridge together, before you plug in anything.
Differential: how far the chamber drifts
The differential (Auber also calls it a "control hysteresis band") is how far the reading has to move past your setpoint before the controller switches a device back on. Auber explains the trade-off plainly: "Small differential gives tight control. Large differential reduces the frequency of cycle on and off, and it will extend the life of relay and compressor" (TH330B manual).
On all three controllers the band is one-sided. Cooling or dehumidifying starts at setpoint plus differential and stops at the setpoint. Heating or humidifying starts at setpoint minus differential and stops at the setpoint. INKBIRD's worked example: with a 25°C set temperature and a 2°C cooling differential, cooling starts at 27°C and stops at 25°C (ITC-308 manual).
Here's where the defaults bite. BCCDC's drying guidance says humidity "should be used with an ideal range of 75-80% at the beginning of the process," that "above 80% moulds may grow," and that "humidity control under 80% will prevent mould growth" (BCCDC 3.13). Our arithmetic with the IHC-200's defaults: set 75% with the 5% dehumidifying differential, and the dehumidifier doesn't start until the display reads 80%. With the maker's ±3% RH accuracy, the real humidity at that moment could be anywhere from 77% to 83%.
Our call: shrink the humidity differential (the IHC-200 goes down to 1% RH) and set the target a little lower, so a high swing still stays under 80%. Then check the real reading with a calibrated hygrometer, not the controller's own screen.
Temperature works the same way. During fermentation, BCCDC says to "Record the temperature of the fermentation room (this temperature must be constant)" (BCCDC 3.13). A 3°F differential each way plus ±2°F accuracy means, by our arithmetic, the true temperature could run 5°F on either side of your setpoint, which is wider than the whole 68 to 75°F range. The degree-hour side of that is in Fermenting salami.
Compressor delay
If a controller runs a fridge or a compressor dehumidifier, set the compressor delay. Auber says it keeps the compressor from "being turned on again when it is at high pressure (i.e., just after it is turned off). Otherwise, it may shorten the life of compressor," and that it "is typically set to 4 - 6 minutes" (TH330B manual). INKBIRD describes the same feature on the ITC-308: "The compressor delay can help protect the refrigeration equipment and improve the equipment's lifetime" (ITC-308 page).
Both the ITC-308 and the TH330B ship with that delay set to 0 minutes, per their own parameter tables. The IHC-200's dehumidifier delay defaults to 1 minute. So "has a compressor delay" on a spec sheet doesn't mean it's switched on. You have to set it.
Probes and sensors in a damp box
A curing chamber is humid on purpose, which is hard on electronics.
- INKBIRD says the ITC-308 "probe is IP68 waterproof, but the body and socket are not," and recommends an aquarium probe or a silicone sleeve "If used in a humid place." The ITC-308 probe is attached; INKBIRD says the ITC-308S has a plug-in probe that is "easy to replace" (ITC-308 page).
- Auber says the TH330B is "designed for high relative humidity (>85%) and condensing environments" (TH330B manual), and its product page explains why that matters in a curing fridge: "opening the fridge door will cause water to condense onto the sensor" (Auber TH330B). That's Auber's claim about its sensor; we haven't tested it.
- The IHC-200 lists its sensor as the HTG3535CH with "Sensor Stability <0.5%RH/yr" (IHC-200 manual).
Our note: keep the controller body outside the chamber, run only the probe or sensor inside, and hang it at salami height, away from the humidifier's output.
Calibration and checking the reading
All three let you dial in an offset. INKBIRD says its controllers "are factory-calibrated," but that "probes are subject to wear and tear during use, which may cause deviations in the readings" (ITC-308 page). Auber's example: "if the unit displays 37ºF when the actual temperature is 32ºF, setting parameter toF = - 5 will make the controller display 32ºF" (TH330B manual).
An offset is only as good as the reference you set it against. Our salt test for hygrometers walks through checking a humidity reading against table salt.
Alarms and what happens when a sensor fails
The default alarms won't help a salami. The ITC-308's high alarm defaults to 248°F and the IHC-200's to 99% RH (ITC-308 manual; IHC-200 manual). That's a great setting for a pizza oven. Our call: set the high and low alarms just outside the band you're actually aiming for, so you hear about a stuck heater or a dry humidifier the same day.
Sensor failure is handled differently by each maker:
- IHC-200. On a short or open sensor, "the controller will initiate sensor fault mode, and cancel all the actions," with a buzzer and "ER" on the display (IHC-200 manual).
- TH330B. You choose. Set the sensor-failure parameter to ON and "the output will always be on when the sensor fails"; set it to OFF and the output stays off. Auber suggests ON for a fridge "to keep the food cold" and OFF for a heater "for safety purpose." Both default to OFF (TH330B manual).
- ITC-308. The manual lists "Short Circuit, Open Circuit, Over Temperature" under sensor error detection. After a power cut, INKBIRD says "your settings will be saved permanently," but recommends you "check the device settings after powering it back on" (ITC-308 manual; ITC-308 page).
A controller doesn't make salami safe
A controller holds the numbers you give it. It can't tell you whether those numbers are right, or whether the meat got there. BCCDC says "Degree-hours must be met for safety," and that drying rooms "must be equipped and monitor air flow, temperature, and humidity" (BCCDC 3.13). The targets themselves are in our home curing chamber guide, Fermenting salami and Drying salami. The rest of the gear list is in Salami equipment. When in doubt, throw it out.
CellarCure is for general education, not professional food-safety or electrical advice. If you're wiring anything beyond plugging a device into a controller's outlet, talk to a licensed electrician. See our full disclaimer.
Sources
- INKBIRD, Temperature Controller ITC-308 Series product page (checked November 24, 2026)
- INKBIRD, ITC-308 user manual (English, V7.0) (checked November 24, 2026)
- INKBIRD, IHC-200 Humidity Controller instruction manual (English) (checked November 24, 2026)
- Auber Instruments, TH330B Temperature & Humidity Controller product page (checked November 24, 2026)
- Auber Instruments, TH330B instruction manual, version 0.9 (April 2024) (checked November 24, 2026)
- BC Centre for Disease Control, Fermented Foods Guidance 3.13: Sausage (checked November 24, 2026)