Spear-Tip pH Meters for Salami: The Specs That Matter

A spear-tip pH meter has a pointed glass sensor you push into the sausage, so you can read pH without blending a slurry. For salami, the number you're reading against is 5.3: fermented sausage has to reach pH 5.3 or lower, and the readings have to be taken from every lot (AMI Foundation GMP). So the specs that matter are the ones that decide whether your meter can tell 5.3 from 5.4 and keep telling it after a month of use. Check four things: accuracy at the display setting you'll actually use, the calibration buffers it takes, the temperature range the probe can stand, and whether you can clean and replace the probe.

This page lines up the published specs of three spear or penetration-tip meters: the Hanna Instruments HI99163 (a meat pH meter), the Hanna HI98161 (a food pH meter) and the Apera Instruments PH60S. They're examples, not picks. We haven't tested any of them, and every number below is the maker's own, from the manual or product page we opened on November 24, 2026. A pointy stick that reads acidity is a better hobby tool than it sounds, but only if it's calibrated, clean and wet.

Why 5.3 sets the spec

The AMI Foundation's guidance for dry and semi-dry sausage says "Fermented and acidulated sausages shall attain a pH of 5.3 or lower," that "it is important to reach a pH below 5.3 to control the growth of pathogenic microorganisms including staphylococci and pathogenic E. coli," and that "pH readings must be taken from each lot" (AMI Foundation GMP, via UW-Madison). BCCDC says "the pH of fresh meat is approximately 5.6-5.8" and that fermentation to pH 5.3 "will be complete on average within 48 hours" (BCCDC 3.13).

Our arithmetic: that's a drop of roughly 0.3 to 0.5 pH units, from the 5.6-5.8 starting range to 5.3. A meter that can only show one decimal can't reliably separate 5.3 from 5.4, which is the whole question. That's why the accuracy line below is tied to the display resolution.

The targets, the time limits and how to take a reading are in pH and water activity. This page is about the hardware.

Side-by-side: what the makers publish

All values are maker claims, checked November 24, 2026. Prices are the maker's own listed price that day and will change.

Spec Hanna HI99163 (meat) Hanna HI98161 (food) Apera PH60S (spear)
Listed price $689.99 $924.99 $248.00 (kit)
Probe in the box FC2323: conical tip with removable stainless steel blade, PVDF body FC2023: conic tip, PVDF body, open junction, no blade Swiss spear probe, double junction, replaceable
pH accuracy ±0.02 pH at 0.01 resolution; ±0.1 pH at 0.1 resolution ±0.01 pH at 0.01; ±0.1 pH at 0.1; ±0.002 pH at 0.001 ±0.01 pH ±1 digit
Display resolution 0.01 or 0.1 pH 0.1, 0.01 or 0.001 pH 0.01 pH (manual); 0.01 or 0.1 (product page)
Calibration points 1 or 2 Up to 5, plus custom buffers 1 to 3
Buffers recognized 4.01, 7.01, 10.01 or 4.01, 6.86, 9.18 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 7.00, 4.00, 10.01, 1.68, 12.45 (manual)
Buffers in the box One sachet each of 4.01 and 7.01 230 mL each of 4.01 and 7.01 4.00, 7.00 and 10.01 plus 3M KCl storage solution
Recalibrate "at least once a month," after cleaning, after a new electrode "At least once a week," after a new electrode No interval stated; setup steps say "at least a 2-point calibration" (manual 3.3)
Probe temperature limit 0 to 50°C (32 to 122°F) Not stated for the probe in what we opened; page says low-temperature glass "suitable for refrigerated products" 0 to 50°C; avoid below 41°F or above 113°F
Probe condition feedback 1 to 5 bars after a two-point calibration Probe condition 0 to 100% after calibration "Self-diagnosis: Yes" (page, no detail)
Cleaning solution in the box 2 sachets, grease and fats acid cleaner 2 sachets, dairy cleaner Not in the kit list (sold separately)
Replacement probe FC2323 (accessory; price not opened) FC2023 (price not opened) PH60S-E, listed at $175.00; 1 to 2 year service life; probe warranty 6 months
Water rating IP67 IP67 IP67

Sources: Hanna HI99163 product page and HI99163 manual (MAN99163_11_18); Hanna HI98161 product page and HI98161 manual; Apera PH60S product page and PH60S manual v7.7.

Read the accuracy line carefully

Accuracy depends on the display setting. The Hanna manuals tie accuracy to resolution. The HI99163 is "±0.02 pH / ±0.1 pH" for its 0.01 and 0.1 settings, and the HI98161 is "±0.1 pH / ±0.01 pH / ±0.002 pH" for 0.1, 0.01 and 0.001 (HI99163 manual; HI98161 product page). Our reading: on the coarse 0.1 setting, either Hanna meter is only good to a tenth of a pH, and the 5.3 line sits inside that. Use the 0.01 setting for salami. Hanna's HI99163 manual lets you change it under setup ("RESOL"), and the HI98161 has a MODE key for resolution.

"±0.01 pH ±1 digit" is not tighter than ±0.02. The PH60S lists "±0.01 pH ±1 digit." Its manual lists a 0.01 pH resolution, so one digit is 0.01, which means a reading can be off by up to 0.02 in the worst case (our arithmetic). That's the same worst case as the HI99163's ±0.02.

The Hanna HI99163 page contradicts its own spec table. The page's bullet list says "±0.2 pH accuracy," while its spec table and the manual say ±0.02 pH (and ±0.1 at the coarse setting). The page also lists 1200 hours of battery life in one place and about 1400 hours in the spec table. On the HI98161, the page gives an operating environment of 5 to 50°C where the manual says 0 to 50°C. We go by the manual and the spec table. Hanna's older manual copy we also opened (MAN99163_05_18) gives accuracy at 20°C, while the current one and the product page say 25°C (older HI99163 manual). If you're comparing listings, make sure you're reading the right line.

What a good spec gets you. Manitoba's pH meter guide says accuracy "is the most important factor in measuring pH" and recommends "a pH meter with an accuracy of at least ±0.02 units" (Manitoba pH Meter Guide). At their finest display settings, all three meters here meet that.

Our margin rule, which no agency writes: with a ±0.02 meter, a displayed 5.28 means the true value is at most 5.30, going by the maker's spec and a fresh calibration. If you want to be sure a batch is at or below 5.3, a reading of 5.28 or lower leaves no gap. A displayed 5.30 or 5.31 on this kind of meter doesn't settle it either way.

Calibration: points, buffers and how often

Manitoba says: "A pH meter must be calibrated against a known standard to assure accuracy each time it is used." It also says to do at least a two-point calibration, using a pH 7.00 buffer and a pH 4.00 buffer for an acidic food (Manitoba pH Meter Guide). The makers' own minimums are looser than that, and they don't match:

  • HI99163: "For better accuracy it is always recommended to carry out a two-point calibration," and the meter "must be recalibrated" after cleaning the sensor, when the electrode is replaced and "at least once a month" (HI99163 manual).
  • HI98161: it should be recalibrated "At least once a week," and Hanna recommends "a calibration with buffers that bracket the expected pH value," with at least two points (HI98161 manual).
  • PH60S: the manual's setup steps for first use say "Perform at least a 2-point calibration," always starting with pH 7.00. The manual gives no recalibration interval. It says the 4.00 and 7.00 buffers in the calibration vials can be reused up to 10 times if they stay clean and capped (PH60S manual v7.7).

Our call: calibrate on the day you use it, with fresh buffer, because Manitoba's "each time it is used" is the strictest line here. The 4.00/7.00 pair brackets the 5.3 you care about. One thing to budget for: the HI99163 ships with one sachet each of 4.01 and 7.01 (one calibration), so plan to buy more buffer.

Temperature: where the probe works

The probe, not the meter body, usually sets the temperature limit. Hanna's manual says the HI99163's FC2323 "is limited to be used from 0 to 12 pH and from 0 to 50 °C" (HI99163 manual). Apera's PH60S manual says to avoid testing "very high (>113°F) or very low (<41°F)" solutions because it "will cause greater measurement error and potential damage to the probe," and to calibrate "close to room temperature as much as possible." It also says "Never use the product when it's freezing cold. Let it warm to room temperature before using" (PH60S manual v7.7).

Manitoba adds that "the pH meter must be calibrated at the same temperature as the samples being tested" (Manitoba pH Meter Guide).

How that lines up with salami (our arithmetic): BCCDC's table puts dry-sausage fermentation at 20 to 24°C and semi-dry at 25 to 45°C (BCCDC 3.13). 45°C is 113°F, right at the PH60S's upper limit, and 41°F is 5°C, so a salami straight from a 4°C (39°F) fridge is under it. The HI99163 probe's 0 to 50°C covers both. Hanna's HI98161 page says its probe has "low temperature pH sensing glass suitable for refrigerated products," though we didn't find a number for it. For a cold sample, let it come up toward your calibration temperature before you read it.

Spearing a sausage

Apera says food readings "should always be a sampling test," meaning the "test samples should no longer be edible," and that if the medium is too hard you should "bore a small hole with a clean knife before inserting the spear probe" (PH60S manual v7.7). Our reading: probe a piece you won't serve, such as a sacrificial link from the same batch, rather than the one you plan to eat.

Hanna's page says the HI99163's stainless steel blade is "razor sharp for easy piercing into meat and other semi-solids while protecting the glass bulb" (HI99163 product page), and its manual lists 20 mm and 35 mm replacement blades (HI99163 manual). The other two have a bare glass spear or cone, which is why the Apera warning about hard samples matters. The aseptic-probing rule and the slurry alternative are in pH and water activity.

Cleaning, storage and probe life

Fat and meat residue coat a probe, and a coated probe reads wrong. Apera says "The tester is only as accurate as the probe is clean," and tells you to rinse before and after each measurement (PH60S manual v7.7). Hanna ships the HI99163 with a grease and fats acid cleaning solution (two sachets) and the HI98161 with a dairy cleaner, and says to recalibrate after cleaning the sensor (HI99163 manual). The PH60S kit list we opened doesn't include a cleaner. Apera's manual names its own probe cleaning solution (AI1166) as a separate item.

Storage is the same rule from both makers: keep the glass tip wet in storage solution and never in pure water. Hanna says "Never store the electrode in distilled water" (HI99163 manual), and Apera says to store the probe in 3M KCl and "NEVER store the probe in pure water" (PH60S manual v7.7).

Probes wear out. Apera says a typical service life is "1-2 years" and recommends replacing it that often, and its warranty covers the instrument for two years but the probe for six months (PH60S manual v7.7). Its page lists the replacement PH60S-E probe at $175.00, which is about 70% of the kit's $248.00 price (our arithmetic). Hanna's HI99163 shows probe condition as 1 to 5 bars after a two-point calibration and says to clean and recalibrate at one bar, then replace the probe if it stays there (HI99163 manual). Hanna's older HI99163 body used a different probe and connector: its page says the old DIN probe connections "are not compatible with the new body design," so check which one you're buying a probe for (HI99163 product page).

Before you buy: a checklist

  1. Accuracy of ±0.02 pH or better (Manitoba's floor), at a display setting that shows two decimals.
  2. Automatic two-point calibration with 4.00 and 7.00 buffers, and a plan for fresh buffer each time.
  3. A probe rated for the temperatures you'll actually read, from a cold fridge sample to a warm fermentation box.
  4. A replaceable probe, with the replacement's price known before you buy the meter.
  5. A cleaning routine for fat, and storage solution on hand, not distilled water.

A pH meter doesn't make salami safe

A meter tells you the pH at the spot you probed. It doesn't tell you the batch reached 5.3 in time, and it doesn't replace the degree-hour limits, the cure or the drying targets. AMI says readings must be taken from each lot, and that's all a meter can do for you: show the number. Washington State University Extension still says "home production of dry sausages is not recommended" (WSU Extension EB1661). What the numbers can and can't promise is covered on our pH and water activity page.

CellarCure is for general education, not professional food-safety advice. Read our disclaimer.

Sources

  1. Hanna Instruments, Portable Meat pH Meter HI99163 product page (checked November 24, 2026)
  2. Hanna Instruments, HI99163 instruction manual, MAN99163_11_18 (checked November 24, 2026)
  3. Hanna Instruments, HI99163 instruction manual, older copy MAN99163_05_18 (checked November 24, 2026)
  4. Hanna Instruments, Professional Foodcare Portable pH Meter HI98161 product page (checked November 24, 2026)
  5. Hanna Instruments, HI98161 instruction manual (checked November 24, 2026)
  6. Apera Instruments, PH60S Premium Spear pH Pocket Tester Kit product page (checked November 24, 2026)
  7. Apera Instruments (Europe), PH60S Spear pH Tester user manual v7.7 (checked November 24, 2026)
  8. Manitoba Agriculture, pH Meter Guide (PDF dated January 27, 2022; checked November 24, 2026)
  9. AMI Foundation, GMP for Fermented Dry and Semi-Dry Sausage (via UW-Madison) (checked November 24, 2026)
  10. BC Centre for Disease Control, Fermented Foods Guidance 3.13: Sausage (checked November 24, 2026)
  11. WSU Extension, Homemade Meat, Poultry, and Game Sausages (EB1661) (checked November 24, 2026)

Internal links