Precision Scales for Curing Salt: The Specs That Matter

Curing salt goes into a salami at a fraction of a percent, so the scale you weigh it on is part of the safety plan, not a kitchen accessory. A scale listing that says "0.01 g" tells you the display step. It doesn't tell you how close the number is to the truth, and those two figures are listed in different places, in different words, by different makers.

This page lines up what four scales publish, turns the error figures into parts per million of nitrite using our own arithmetic, and flags where a maker's page and its manual don't agree. The scales are examples, not picks. We haven't tested any of them, and we don't rank them. Every number below is the maker's own, from a page or manual we opened on November 24, 2026, and prices are the listed prices that day. For why we weigh cure at all, see Salami equipment and Curing salts. This page is only about reading the specs.

Why the error matters here

Our recipe uses Curing Salt #2 at 0.25% of the meat block, which is 2.5 g per 1,000 g of meat. That comes to about 156 ppm of nitrite, which our recipe guide notes is the federal limit for chopped meat ("With a 6.25% nitrite cure, 0.25% already sits right at that 156 ppm limit, so don't round up"). On the low side, BCCDC says fermented sausage "must be cured, having at least 100 ppm and no more than 200 ppm" (BCCDC 3.13).

Here's what a scale error does to that dose. This is our arithmetic, for a cure that's 6.25% nitrite, where each 0.1 g of cure per kilogram of meat adds 6.25 ppm:

Scale error on the cure Share of a 2.5 g dose Nitrite change, 1 kg of meat Nitrite change, 5 kg of meat
±0.01 g 0.4% ±0.625 ppm ±0.125 ppm
±0.02 g 0.8% ±1.25 ppm ±0.25 ppm
±0.1 g 4% ±6.25 ppm ±1.25 ppm
±0.2 g 8% ±12.5 ppm ±2.5 ppm
±0.3 g 12% ±18.75 ppm ±3.75 ppm

A scale that's 0.2 g high on a 1 kg batch puts 2.7 g in the mix. That's about 169 ppm, past the 156 ppm our guides treat as the ceiling. A scale that's 0.2 g low is about 144 ppm, which is still above BCCDC's 100 ppm floor. Bigger batches shrink the percentage, because the same error is spread over more meat. Weighing the meat itself is far more forgiving: 2 g off on 1,000 g of meat is 0.2% (our arithmetic), so the cure is the weighing that needs the better scale.

Two university sources say the same thing from the other side. University of Georgia (UGA) Extension says "Since these small quantities are difficult to weigh on most available scales, it is strongly recommended that a commercial premixed cure be used" (UGA Extension B1437). Washington State University (WSU) Extension says "Since it is difficult to accurately weigh the small quantities needed, it is necessary to use a preblended commercial curing mix" (WSU Extension EB1661). The 6.25% figure above is for a premixed cure, which is what both sources tell you to use. The scale only has to get the premix right.

Four scales, side by side

AWS-100 AWS-1KG Tanita KD-321 Ohaus Scout SKX2201
Listed price (Nov 24, 2026) $16.99 $19.99 $89.95 CAD at one Canadian retailer, out of stock Not opened
Capacity x readability 100 g x 0.01 g 1,000 g x 0.1 g 3,000 g; 0.1 g up to 300 g, 0.5 g from 300 to 1,500 g, 1 g standard 2,200 g x 0.1 g
Accuracy figure the maker gives ±0.02 g (acceptable tolerance in the manual's calibration check) ±0.2 g (same manual check); the page says "accuracy to within 0.1 gram" ±0.2 g from 0 to 75 g and ±0.3 g from 75 to 300 g in 0.1 g mode Repeatability 0.1 g (standard deviation); linearity 0.1 g
Calibration 100 g weight, not included 500 g weight, not included No calibration weight in what we opened; a region (gravity) setting instead, which the retailer calls "Region setting (gravity adjustment)" User span or linearity calibration with an external mass; span mass is 2 kg
Tare The container's weight "will subtract from the available capacity" Same The display step depends on the total on the pan, container included (manual, our translation) "Full Capacity by subtraction"
Operating conditions in the maker's own words "Avoid exposure to extreme heat or cold" Same Accuracy table given for 23°C ±5°C and humidity below 60% (our translation of the manual) Specified range 10°C to 40°C (50°F to 104°F)
Warranty 10-year limited 10-year limited 1 year, batteries excluded (manual, our translation) Limited warranty; the manual gives no length and says to contact Ohaus or a dealer

Sources: American Weigh Scales (AWS) AWS-100 page, AWS-1KG page and AWS-Series manual; a Tanita KD-321 retailer page and Tanita's manual; the Ohaus Scout SKX manual.

Readability is not accuracy

The "x 0.01 g" in a listing is the readability: the smallest step the display shows. Accuracy is a separate claim, and the makers word it differently:

  • AWS doesn't give an accuracy line in its spec table. Its manual gives an "Acceptable Tolerance" for the calibration check: ±0.02 g for the 0.01 g models and ±0.2 g for the 0.1 g models. It says the check is done by putting the calibration weight on the scale and seeing whether the reading falls inside that tolerance. That's tolerance at the calibration weight (100 g or 500 g). None of the AWS pages we opened says what the error is at 2.5 g.
  • Tanita gives accuracy in bands: ±0.2 g from 0 to 75 g, ±0.3 g from 75 to 300 g in its 0.1 g micro mode, and ±2 g or ±3 g in standard mode, per the retailer's copy of the manufacturer specification. Tanita's own manual shows the same figures. Its first band starts at zero, so it covers a 2.5 g dose.
  • Ohaus gives repeatability and linearity as separate numbers. Repeatability is how much repeated readings of one weight scatter. Linearity is how far the response drifts from a straight line across the range. For the SKX2201 both are 0.1 g, the same as the readability.

So "0.1 g" can mean ±0.1 g or ±0.2 g depending on the maker, and none of the three terms is the same as another. Our reading: for a 2.5 g dose per kilogram, one 0.1 g step is already a 4% change, so a 0.1 g scale is thin ground for weighing cure, and a ±0.2 g scale is thinner. That's why the table above is a better guide than the readability figure.

AWS's own pages show how easy it is to blur these. The AWS-1KG page says its calibration gives "unparalleled accuracy to within 0.1 gram," while the same maker's manual allows ±0.2 g for the calibration check on that model. Both can be read as true, because one describes the display step and the other a tolerance, but a buyer reading only the page would expect half the error. The same goes for the AWS-100, where the display step and the tolerance differ by a factor of two (0.01 g and ±0.02 g).

Capacity, tare and a 1 kg meat block

Capacity has a catch when you weigh the whole batch. AWS's manual says "The weight of the container will subtract from the available capacity." Our recipe's meat block is 1,000 g, so that meat alone fills a 1,000 g scale like the AWS-1KG, and it's over capacity once you add a bowl (our arithmetic). The manual's error code 88888 means "Maximum capacity exceeded. Remove the extra weight to avoid damaging the load cell." The Ohaus SKX2201 (2,200 g) leaves room, and its tare is listed as "Full Capacity by subtraction."

The Tanita works differently. Its 0.1 g step only runs to 300 g on the pan, then moves to 0.5 g until 1,500 g, and 1 g above that, so on this scale a kilogram of meat is weighed in 0.5 g steps, not 0.1 g. In that 0.5 g micro mode the stated accuracy is ±1.0 g up to 375 g and ±1.5 g from 375 to 1,500 g, so a 1 kg block is weighed to about ±1.5 g. That's 0.15% of the meat (our arithmetic), which is fine for the meat. It isn't a number you'd want on the cure.

That points to a two-step setup, which is our reading of the specs and not a rule from any source: a small scale with a 0.01 g step for the cure, and any scale with enough capacity for the meat. Our recipe's equipment table lists one digital scale at "0.1 g," which is the weaker option by the numbers above.

Ounces are coarser than grams

Our How to make salami at home lists "Digital scale (0.1 g / 0.01 oz)." Those two aren't the same step. Our arithmetic: 0.01 oz is about 0.28 g. AWS's manual shows the effect: the AWS-1KG reads 1000 x 0.1 g in grams and 35.2 x 0.01 oz in ounces, so the ounce display steps nearly three times as far as the gram display. The AWS-100 reads 0.001 oz, but we found that only in the manual's chart. Weigh cure in grams, and use the calculator's gram amounts (see our cure calculator).

Calibration: the weights cost extra

UGA says "Always calibrate your scale before using it to weigh out the proper amounts" (UGA Extension B1437). What that means differs by scale:

  • AWS: "Calibration and adjustment are performed at the factory. However, the weighing range can shift slightly during shipping." The manual recommends checking it "occasionally," and says "If temperatures have changed dramatically, recalibration may be necessary." The weight is a separate purchase: 100 g for the AWS-100 and 500 g for the AWS-1KG. The manual lists "OIML M2" as the recommended accuracy class. AWS lists an AWS-100-CAL model that includes a weight, and it was out of stock when we looked.
  • Ohaus: "When the balance is operated for the first time, a span calibration is recommended." It needs the 2 kg span mass for the SKX2201, and the manual says calibration weights are included only with models up to 620 g capacity, and only "for certain regions." It also says to let the balance "warm up for at least 5 minutes before using it."
  • Tanita: no calibration weight is called for in what we opened. Its manual says (our translation) that high-precision scales can read slightly differently by region because of gravity, and has you set your region. If you can't check a scale against a known weight, you can't tell whether a stated accuracy still holds on your counter (our reading).

Environment counts too. The AWS manual says to weigh "on a flat and level surface, free from vibrations and drafts" and to avoid "strong radio wave emitting devices such as cordless phones." Ohaus says not to use its balance "in environments with excessive drafts, with rapid temperature changes." If you're working in a cold room, check your scale's stated temperature range first. Ohaus's specified range starts at 10°C (50°F).

Before you buy: a checklist

  1. Find the accuracy, tolerance or linearity figure, not just the readability.
  2. Check that the accuracy figure applies at a small weight like 2.5 g, not only at the calibration weight.
  3. Compare capacity with your biggest batch plus its bowl.
  4. Find what calibration weight the scale needs, and whether it's in the box.
  5. Weigh the cure in grams.
  6. Check the stated temperature and humidity range against where you'll use it.
  7. Plan on weighing the cure twice, as our recipe says, and keep the calculator's grams in front of you.

A better scale doesn't make a batch safe

A scale gets the cure amount right. It doesn't choose the right cure for the product, the right amount for your meat weight, or the drying time. Our cure calculator turns your meat weight into grams, and Curing salts explains which cure to use for which product. Don't eyeball the cure, and don't round up. When in doubt, throw it out.

CellarCure is for general education, not professional food-safety advice. Read our disclaimer.

Sources

  1. American Weigh Scales, AWS 100g Digital Pocket Scale Series (AWS-100) product page (checked November 24, 2026)
  2. American Weigh Scales, AWS 1kg Digital Pocket Scale Series (AWS-1KG) product page (checked November 24, 2026)
  3. American Weigh Scales, AWS-Series User Manual, Rev. 8 (checked November 24, 2026)
  4. Gusta Supplies, Tanita KD-321 Micro Kitchen Scale product page (retailer's copy of the manufacturer specification) (checked November 24, 2026)
  5. Tanita, KD-321 instruction manual (Chinese-language PDF) (checked November 24, 2026)
  6. Ohaus, Scout SKX Series Portable Balance Instruction Manual (checked November 24, 2026)
  7. University of Georgia Extension, B1437: Basics of Sausage Making (checked November 24, 2026)
  8. WSU Extension, Homemade Meat, Poultry, and Game Sausages (EB1661) (checked November 24, 2026)
  9. BC Centre for Disease Control, Fermented Foods Guidance 3.13: Sausage (checked November 24, 2026)